Physical
Properties of KLEENGUARD® Extra Apparel Fabric
Physical
Properties
Test
method
Results
Tensile
Strength (MD)
ASTM
D5034
29.7
lbs
(CD)
20.8
lbs
Trapezoidal
Tear (MD)
INDA
IST 100.2
9.9
lbs
(CD)
6.9
lbs
Elongation
(MD)
ASTM
D5034
41%
(CD)
53%
Mullen
Burst
ISO
13938-1
42.5
psi
Static
Decay (<0.5 sec)
NFPA
99
Pass
Flammability
CPSC
1610
Class
1
Barrier
Properties
Test
method
Results
Hydrohead
AATCC
127-194
88.2
cm
Comfort
Properties
Test
method
Results
Air
Permeability
ASTM
D737
29.5
cfm
MVTR
ASTM
E96
4506
g/m2/24 hr
Physical
Properties of KLEENGUARD® Finishing Protection
Apparel Fabric
Physical
Properties
Test
method
Results
Tensile
Strength (MD)
ASTM
D5034
25.3
lbs
(CD)
23
lbs
Trapezoidal
Tear (MD)
INDA
IST 100.2
4.8
lbs
(CD)
6.1
lbs
Elongation(%)
(MD)
ASTM
D5034
47.8%
(CD)
50.6%
Mullen
Burst
ISO
13938-1
40
psi
Static
Decay (<0.5 sec)
NFPA
99
Pass
Flammability
CPSC
1610
Class
1
Barrier
Properties
Test
method
Results
Hydrohead
AATCC
127-1998
52.4
cm
Comfort
Properties
Test
method
Results
Air
Permeability
ASTM
D737
22.3
cfm
MVTR
ASTM
E96
4609
g/m2/24 hr
Physical
Properties of KLEENGUARD® Select Apparel Fabric
Physical
Properties
Test
method
Results
Tensile
Strength (MD)
ASTM
D5034
26.4
lbs
(CD)
17.2
lbs
Trapezoidal
Tear (MD)
INDA
IST 100.2
9.2
lbs
(CD)
4.8
lbs
Elongation
(MD)
ASTM
D5034
45%
(CD)
56.7%
Mullen
Burst
ISO
13938-1
36.4
psi
Static
Decay (<0.5 sec)
NFPA
99
Pass
Flammability
CPSC
1610
Class
1
Barrier
Properties
Test
method
Results
Hydrohead
AATCC
127-1998
72.8
cm
Comfort
Properties
Test
method
Results
Air
Permeability
ASTM
D737
41.8
cfm
MVTR
ASTM
E96
4639
g/m2/24 hr
Physical
Properties of KLEENGUARD® Ultra Apparel Fabric
Physical
Properties
Test
method
Results
Tensile
Strength (MD)
ASTM
D5034
27.2
lbs
(CD)
18.7
lbs
Trapezoidal
Tear (MD)
INDA
IST 100.2
7.1
lbs
(CD)
4.3
lbs
Elongation
(MD)
ASTM
D5034
37.9%
(CD)
61.7%
Mullen
Burst
ISO
13938-1
40.6
psi
Static
Decay (<0.5 sec)
NFPA
99
Pass
Flammability
CPSC
1610
Class
1
Barrier
Properties
Test
method
Results
Hydrohead
AATCC
127-1998
226
cm
Blood
Penetration
ASTM
F1670
Pass
Blood-Borne
Pathogens
ASTM
F1671
Pass
Comfort
Properties
Test
method
Results
MVTR
ASTM
E96
2725
g/m2/24 hr
Standard Test Method for Resistance of Materials Used in Protective
Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174
Bacteriophage Penetration as a Test System.
Liquid
Chemical Resistance Test/ KLEENGUARD® Ultra Fabric
When
selecting chemical protective clothing, its important to be
sure that the garment offers adequate resistance to the chemicals
being handled in your workplace.
ASTM
F1001 Liquid Chemicals
PENETRATION
ASTM F903
(Procedure C)
Carbon
Disulfide
Pass !
Dichloromethane
Pass
!
n-Hexane
Pass
Sodium
Hydroxide (50%)
Pass
Sulfuric
Acid (97%)
Pass
Tetrahydrofuran
Pass
Sodium
Hypochlorite
(100% household bleach)
Pass
Valspar
Isocyanate Hardener (100%)
Pass
!
!
WARNING: Fabric passes penetration testing; however,
the chemical is a known or suspected carcinogen or skin absorbed
toxin.
KLEENGUARD®
Ultra Coveralls vs. TYVEK*
Fabric
Used In KLEENGUARD® Ultra Coverallss
Garments
made of TYVEK*
Provides
impervious protection from contact with blood and body fluids (Test
ASTM F1670)
PASS
FAIL
Resists
penetration of blood-borne pathogens (Test ASTM F1671)
PASS
FAIL
Energy
that fabric can absorb without breaking (Test ASTM D1682)
18.2
in/lb
7.7
in/lb
Liquid
resistance under pressure
(Hydrohead Test AATCC 127-1989)
226
mbars
111
mbars
Standard Test Method for Resistance of Materials Used in Protective
Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174
Bacteriophage Penetration as a Test System.
*®Tyvek
is a Registered Trademark of the DuPont Company.
Standard Test Method for Resistance of Materials Used in Protective
Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174
Bacteriophage Penetration as a Test System.
*®Tyvek
is a Registered Trademark of the DuPont Company.
Physical
Properties of HAZARD-GARD* I Apparel Fabric
Physical
Properties
Test
method
Results
Tensile
Strength (MD)
ASTM
D5034
40.1
lbs
(CD)
31.1
lbs
Trapezoidal
Tear (MD)
INDA
IST 100.2
14.8
lbs
(CD)
9.4
lbs
Mullen
Burst
ISO
13938-1
46.8
psi
Flammability
CPSC
1610
Class
1
Barrier
Properties
Test
method
Results
Hydrohead
AATCC
127-1998
378
cm
Blood
Penetration
ASTM
F1670
Pass
Blood-Borne
Pathogens
ASTM
F1671
Pass
Standard Test Method for Resistance of Materials Used in Protective
Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174
Bacteriophage Penetration as a Test System.
LIQUID
CHEMICAL RESISTANCE TEST/HAZARD-GARD* I Apparel Fabric
When
selecting chemical protective clothing, its important to be
sure that the garment offers adequate resistance to the chemicals
being handled in your workplace.
Additional
testing information and detail is available upon request.
!
WARNING: Fabric passes penetration testing; however,
the chemical is a known or suspected carcinogen or skin absorbed
toxin.
Physical
Properties of HAZARD-GARD* II Apparel Fabric
Physical
Properties
Test
method
Results
Tensile
Strength (MD)
ASTM
D5034
52.8lbs
(CD)
40
lbs
Trapezoidal
Tear (MD)
INDA
IST 100.2
19.6
lbs
(CD)
9.5
lbs
Mullen
Burst
ISO
13938-1
54.3
psi
Flammability
CPSC
1610
Class
1
Barrier
Properties
Test
method
Results
Hydrohead
AATCC
127-1998
625
cm
Blood
Penetration
ASTM
F1670
Pass
Blood-Borne
Pathogens
ASTM
F1671
Pass
Standard Test Method for Resistance of Materials Used in Protective
Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174
Bacteriophage Penetration as a Test System.
LIQUID
CHEMICAL RESISTANCE TEST/HAZARD-GARD* II Apparel Fabric
When
selecting chemical protective clothing, its important to be
sure that the garment offers adequate resistance to the chemicals
being handled in your workplace.
Additional
testing information and detail is available upon request.
!
WARNING: Fabric passes penetration testing; however,
the chemical is a known or suspected carcinogen or skin absorbed
toxin.
Physical
Properties of PREVAIL® Apparel Fabric
Physical
Properties
Average
Results
Flammability
Pass
NFPA
701
Trap
Tear
Lbs.
5.7
INDA
IST 100.2
Mullen
Burst
PSI
43
psi
ASTM
E96-80
Tensile
Strength
Lbs.
27.7
ASTM
D5034
Air
Permeability
Cfm
56
ASTM
D737
MVTR
(Moisture Vapor Transport Rate)
G/m2/24
hrs
4528
ASTM
E96
Antistat
Pass/Fail
Pass
NFPA
99
Physical
Properties of REPEL® Apparel Fabric
Physical
Properties
Test
method
Results
Tensile
Strength (MD)
ASTM
D5034
25.1
lbs
(CD)
19.6
lbs
Trapezoidal
Tear (MD)
INDA
IST 100.2
9.4
lbs
(CD)
6.6
lbs
Elongation
(MD)
ASTM
D5034
47%
(CD)
56.6%
Mullen
Burst
ISO
13938-1
36.8
psi
Flammability
CPSC
1610
Class
1
Barrier
Properties
Test
method
Results
Hydrohead
AATCC
127-1998
277
cm
Blood
Penetration
ASTM
F1670
Pass
Blood-Borne
Pathogens
ASTM
F1671
Pass
Standard Test Method for Resistance of Materials Used in Protective
Clothing to Penetration by Blood-Borne Pathogens Using Phi-X174
Bacteriophage Penetration as a Test System.
LIQUID
CHEMICAL RESISTANCE TEST/REPEL® Apparel Fabric
When
selecting chemical protective clothing, its important to be
sure that the garment offers adequate resistance to the chemicals
being handled in your workplace.
ASTM
F1001 Liquid Chemicals
PENETRATION
ASTM F903
Acetone
Pass
Acetonitrile
Pass
!
Carbon
Disulfide
Pass !
Dichloromethane
Pass
!
Diethylamine
Pass
!
n,n-Dimethylformamide
Pass
!
Ethyl
Acetate
Pass
n-Hexane
Pass
Methanol
Pass
!
Nitrobenzene
Pass
!
Sodium
Hydroxide (50%)
Pass
Sulfuric
Acid (98%)
Pass
Tetrachloroethylene
Pass
!
Tetrahydrofuran
Pass
Toluene
Pass
!
!
WARNING: Fabric passes penetration testing; however,
the chemical is a known or suspected carcinogen or skin absorbed
toxin.